MICROPHONE CABLES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

Microphone cables intended for connecting movable electroacoustics, electronics and monitoring devices.

The cables are suitable for indoor installations connecting fixed and movable equipment.

CONSTRUCTION of YPMX; YPMXekw; YPMXekż; YPMXekżp

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request),

- polyethylene (PE) insulation - identification colour code according to PN-T-90222,

- individual shield with copper wire lapping (ekż),

- individually shielded cores laid parallel to one another along the cable (YPMXekżp),

- cores or individually shielded cores laid-up into cable core,

- overall shield with copper wire lapping (ekw),

- black (RAL 9005) PVC cable sheath, other colours also available.

CONSTRUCTION of YPMY; YPMYekw; YPMYekż

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request),

- PVC insulation - identification colour code according to PN-T-90221,

- individual shield with copper wire lapping (ekż),

- cores or individually shielded cores laid-up into cable core,

- overall shield with copper wire lapping (ekw),

- black (RAL 9005) PVC cable sheath, other colours also available.

CHARACTERISTICS

Conductor cross-section

mm2

0.05

0.08

0.12

0.15

0.20

0.50

DC conductor resistance at 20°C

Ω/km

400

270

170

150

105

39

 



Operating voltage

Voltage test

Insulation resistance, minimum

     PE insulation

    PVC insulation

Mutual capacitance shielded and

unshielded conductors to other

conductors and screens connected together, appr.

     PE insulation

     PVC insulation

 

150 V

500 V rms

 

100 MΩ·km

10 MΩ·km

 

 

 

140 pF/m

300 pF/m

Operating temperature range

      during operation

      during installation

Minimum bending radius

Cable combustibility

Combustibility tests

 

Reference standards

 

from - 30 to + 70°C

from   - 5 to + 50°C

10 x cable diameter

flame retardant

PN-EN 60332-1-2, PN-EN 60332-2-2,

IEC 60332-1-2, IEC 60332-2-2

PN-T-90221, PN-T-90222

 The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and conductor counts available on request.