FLAT LIFT CABLESS Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

H07VVH6-F are flexible power and control cables designed for trolley systems, transport lines, machine tools, especially on hosting devices, lift, crane worked in dry and wet locations.

The cables are designed to offer high flexibility combined with tensile strength.

Cable outer sheath is oil-resistant.

The cables are suitable for connecting fixed and movable equipment in dry or wet locations.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

- PVC insulation  - identification colour code:

up to 5 cores - in accordance with PN-HD 308,

from 6 cores - black and white conductor number printed on it,

optional green-yellow protective conductor located near the axis of the cable,

- insulated conductors laid parallel side by side in groups along the cable,

- black PVC cable sheath, other colours also available.

CHARACTERISTICS

Conductor cross-section

mm2

1.5

2.5

4.0

6.0

10

DC conductor resistance at 20°C, maximum

Ω/km

13.30

7.98

4.95

3.30

1.91

DC insulation resistance at 70°C, minimum

MΩ·km

0.0100

0.0090

0.0070

0.0060

0.0056

Operating voltage Uo/U    450/750 V
Voltage test    2500 V rms
Maximum length of the free suspension    35 m

Maximum speed movement    1.6 m/s

Conductor temperature limit
      in work conditions         + 70°C
      at short-circuit              + 150°C

Operating temperature range
      for fixed equipment               from - 40 to + 70°C
      for movable equipment          from - 20 to + 70°C

Minimum bending radius              10 x cable height

Cable combustibility                     flame retardant

Combustibility tests                      PN-EN 60332-1-2, IEC 60332-1-2

Reference standards                    DIN VDE 0281 part 404, HD 359

                                                    

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and conductor counts available on request.

Attention:       For cable with green-yellow protective conductor, instead mark „x” in cable symbol

                      is used letter ”G”.

      Cable marking, for example:

                                H07VVH6-F 4x1,5 mm2 – cable without green-yellow protective conductor,

H07VVH6-F 4G1,5 mm2 – cable with green-yellow protective conductor.