DATA TRANSMISSION CABLE Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

RE-2Y(St)Yv are multipair, overall shielded cables intended for control and instrumentation circuits, for signal, monitoring and data processing systems and for analogue or digital data transmission, all in industrial electronics applications.

High digital data transmission performance is achieved by polyethylene insulation and small capacitance of cable circuits.

The cables are protected by an overall electrostatic shield against external electric interferences.

The cables are suitable for indoor and outdoor installations in dry and wet locations, also for direct earth burial.

Cable outer sheath is oil-resistant.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 2 per PN-EN 60228,

- polyethylene (PE) insulation - identification colour code:

    ”a” wire – black insulation and white pair number printed on it,

    ”b” wire – white insulation and black pair number printed on it,

- insulated conductors twisted into pairs,

- pairs and an orange communication conductor laid-up into a cable core,

- cable core wrapped in polyester tape,

- overall electrostatic shield incorporating aluminium-polyester tape and stranded annealed tinned copper drain wire,

- enhanced PVC cable sheath, black RAL 9005 or blue RAL 5015 (for intrinsically safe circuits).

AVAILABLE UPON REQUEST

RE-2Y(St)Yv-O - cables designed for frequent contact with petroleum products, as in petrol stations and stores, where engine fuels and lubricants are pumped or handled. The cable sheath is then made of special PVC compound meeting oil resistance requirements of Polish standard PN-EN 60811-404.

 

CHARACTERISTICS

Conductor cross-section

mm2

0.5

0.75

1.3

DC loop resistance at 20°C, maximum

Ω/km

78.0

52.0

28.4

Mutual capacitance at 1 kHz, approximate

nF/km

60

65

75

 

Operating voltage, peak value

Voltage test

Insulation resistance, minimum

Inductance, approximate

300 V

2.0 kV rms

5 GΩ·km

0.7 mH/km

Operating temperature range

      for fixed installation

      for movable installation

Minimum bending radius

Cable combustibility

Combustibility tests

Reference standards

 

from - 30 to + 80°C

from   - 5 to + 50°C

10 x cable diameter

flame retardant

PN-EN 60332-1-2, IEC 60332-1-2

PN-EN 50288-7

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and pair counts available on request.

TECHNOKABEL S.A. reserves the right to change specifications without prior notice.