MICROPHONE CABLES | Technical Data sheet |
|
|
APPLICATIONS
Microphone cables intended for connecting movable electroacoustics, electronics and monitoring devices.
The cables are suitable for indoor installations connecting fixed and movable equipment.
CONSTRUCTION of YPMX; YPMXekw; YPMXekż; YPMXekżp
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request),
- polyethylene (PE) insulation - identification colour code according to PN-T-90222,
- individual shield with copper wire lapping (ekż),
- individually shielded cores laid parallel to one another along the cable (YPMXekżp),
- cores or individually shielded cores laid-up into cable core,
- overall shield with copper wire lapping (ekw),
- black (RAL 9005) PVC cable sheath, other colours also available.
CONSTRUCTION of YPMY; YPMYekw; YPMYekż
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request),
- PVC insulation - identification colour code according to PN-T-90221,
- individual shield with copper wire lapping (ekż),
- cores or individually shielded cores laid-up into cable core,
- overall shield with copper wire lapping (ekw),
- black (RAL 9005) PVC cable sheath, other colours also available.
CHARACTERISTICS
Conductor cross-section |
mm2 |
0.05 |
0.08 |
0.12 |
0.15 |
0.20 |
0.50 |
DC conductor resistance at 20°C |
Ω/km |
400 |
270 |
170 |
150 |
105 |
39 |
Voltage test Insulation resistance, minimum PE insulation PVC insulation Mutual capacitance shielded and unshielded conductors to other conductors and screens connected together, appr. PE insulation PVC insulation
|
150 V 500 V rms
100 MΩ·km 10 MΩ·km
140 pF/m 300 pF/m |
Operating temperature range during operation during installation Minimum bending radius Cable combustibility Combustibility tests
Reference standards |
from - 30 to + 70°C from - 5 to + 50°C 10 x cable diameter flame retardant PN-EN 60332-1-2, PN-EN 60332-2-2, IEC 60332-1-2, IEC 60332-2-2 PN-T-90221, PN-T-90222 |
The cable meets requirements of the low voltage directive 2014/35/EU
Other cross-sections and conductor counts available on request.
TECHNOKABEL S.A. reserves the right to change specifications without prior notice.