LOCAL AREA NETWORK CABLES | Technical Data sheet |
|
|
APPLICATIONS
TECHNODATA LAN-T2 3x2x0,75 mm2 cable is intended for industrial and other dedicated networks sensitive to electromagnetic interferences.
Moisture barrier is made of plastic laminated aluminium tape longitudinally applied over a cable core and bonded to polyethylene (PE) cable sheath. The cable core is filled with petro-gel to protect the cable against moisture penetration along the cable.
Sheathing polyethylene (PE) is halogen free and UV radiation and weather resistant, however, it is not self-extinguishing and flame retardant.
The cable is suitable for outdoor installations, laying in ducts and direct earth burial.
CONSTRUCTION
- flexible, multiwire conductors, stranded of annealed tin-plated copper wires, cross-section 0.75 mm2,
- foam-skin polyethylene (PE) insulation coloured: white and brown, white and green, white and yellow,
- insulated conductors twisted into pairs,
- pairs laid-up into a cable core,
- cable core filled-up with petro-gel and wrapped in a polyester tape,
- moisture barrier and additional cable shielding made of a plastic laminated aluminium tape and a drain wire under the tape longitudinally applied over the cable core,
- black polyethylene (PE) cable sheath.
AVAILABLE UPON REQUEST
TECHNODATA LAN-T2n 3x2x0,75 mm2 - cable intended for suspension on poles. The cable is integrated with a steel rope by an 8 shape polyethylene (PE) common sheath.
TECHNODATA LAN-T2-FOR 3x2x0,75 mm2 - cables with additional covering which is then made of special oil-resistant, self-extinguishing PVC of higher oxygen index. Cables are dedicated for indoor installations and in locations where oil-resistant and flame retardant is required.
CHARACTERISTICS
Characteristic impedance 100 ± 15 Ω
Mutual capacitance of any pair at 1 kHz, approximate 56 nF/km
Capacitance unbalance of anypair to ground at 1 kHz, max. 1600 pF/km
Insulation resistance, minimum 150 MΩ∙km
Operating voltage 150 V
Voltage test 700 V rms
Velocity of propagation 65 %
Return loss, minimum at f=1-10 MHz 23 dB
Return loss, minimum at f=1-200 MHz 75 dB
Shielding impedanceat 10 MHz, maximum 10 mΩ/m
DC loop resistance at 20°C, maximum 52 Ω/km
Resistance unbalance of any pair of conductors, max. 3 %
Operating temperature range
during operation from - 40 to + 70°C
during installation from -10 to + 50°C
Minimum bending radius 12 x cable diameter
Reference standards PN-EN 50173, ISO/IEC 11801
Frequency |
Attenuation loss, maximum dB/100m |
Near end cross-talk for cable length ≥ 100 m minimum dB |
1.0 |
1.3 |
41.3 |
2.0 |
1.8 |
36.8 |
4.0 |
2.6 |
32.3 |
6.0 |
3.2 |
29.6 |
8.0 |
3.7 |
27.8 |
10.0 |
4.3 |
26.3 |
The cable meets requirements of the low voltage directive 2014/35/EU