HOOK-UP WIRES | Technical Data sheet |
|
|
APPLICATIONS
TDY and TDYd (with thicker insulation) - are hook-up wires intended for use in remote control, signal and data transmission and industrial data processing systems and computer networks.
Generally, they are designed for control cabinets, electronic devices and others as interconnection cables for electronic modules, equipment and instruments.
CONSTRUCTION
- bare annealed copper single wire conductors (tin-plated on request),
- PVC insulation - identification colour code in accordance with PN-91/T-90206,
- in case of multiwire cables, insulated conductors twisted into pairs, triads or quads.
AVAILABLE UPON REQUEST
TDYc - wires with heat resistant PVC insulation up to 90°C (on request for temperature up to 105°C - TDYc 105°C).
CHARACTERISTICS
Conductor diameter |
mm |
0.4 |
0.5 |
0.6 |
0.8 |
1.0 |
DC conductor resistance at 20°C, maximum single-wires multi-wires |
Ω/km |
144.0 148.0 |
92.0 95.0 |
64.0 65.9 |
36.0 36.7 |
22.8 23.3 |
Voltage test |
V rms |
1000 |
1000 |
1000 |
1500 |
1500 |
Operating voltage Insulation resistance, min Operating temperature range for fixed installation for movable installation |
150 V 200 MΩ·km
from - 20 to + 70°C from - 5 to + 50°C |
Minimum bending radius Wire combustibility Combustibility tests
Reference standards |
10 x wire diameter flame retardant PN-EN 60332-1-2, IEC 60332-1-2 PN-EN 60332-2-2, IEC 60332-2-2 PN-91/T-90200, PN-91/T-90206 |
The cable meets requirements of the low voltage directive 2014/35/EU
c - tinned copper conductor.
Other conductor diameters and conductor counts available on request.
TECHNOKABEL S.A. reserves the right to change specifications without prior notice.