RAILWAY WIRES
Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

TECHNORAY-3 halogen free single-core wires are intended for fixed and mobile connections in vehicles, rolling stock and transport. Wires can also be used for control, protection and monitoring systems or power supply.

The wires are designed to offer high flexibility combined with tensile strength.

Continuous operation at higher temperatures and a high level of fire safety is offered due to application of electron beam crosslinked halogen free compound insulation.

Halogen free wires are applied in locations where, in case of fire, higher safety level for human beings and expensive electronic equipment is required. The wires are flame retardant and their smoke emission is low, emitted fumes are non toxic and non corrosive.

The wires are designed for frequent contact with petroleum products. The wire insulation is then made of special halogen free compound meeting oil resistance requirements of Polish standard PN-EN 60811-404.

Wires are approved by the Institute of Railways for use in vehicles, rolling stock and transport.

CONSTRUCTION

- flexible, multiwire conductors, stranded of annealed tinned copper wires, meeting requirements of class 5per PN-EN 60228,

- dual wall insulation made of electron beam crosslinked halogen free compound (EI 104), black, other colours also available.

CHARACTERISTICS

Conductor cross-section

mm2

0.5

0.75

1

1.5

2.5

4

6

DC conductor resistance at 20°C, maximum

Ω/km

40.1

26.7

20.0

13.7

8.21

5.09

3.39

Conductor cross-section

mm2

10

16

25

35

50

70

95

DC conductor resistance at 20°C, maximum

Ω/km

1.95

1.24

0.795

0.565

0.393

0.277

0.210

 

Operating voltage Uo/U

Voltage test

Corrosivity of emitted gases per             

 

 

      pH appr.

      conductivity appr.

Smoke density

 

      light transmittance, minimum

600/1000 V

3.5 kV rms

PN-EN 60754-1,

PN-EN 60754-2,

IEC 60754-2

6

0.8 µS/mm

PN-EN 61034-2,

IEC 61034-2

90 %

Operating temperature range

Minimum bending radius:

   for fixed installation

 

   for movable installation

  

Wire combustibility

Combustibility tests

 

 

Oil resistance

Reference standards

from - 40 to + 120°C (20 000 h)

 

D≤10 mm - 3 x wire diameter

D>10 mm - 4 x wire diameter

D≤10 mm - 5 x wire diameter

D>10 mm - 6 x wire diameter

flame retardant

PN-EN 60332-1-2, IEC 60332-1-2

PN-EN 60332-3-22, IEC 60332-3-22 (cat. A)

PN-K-02508

PN-EN 60811-404

PN-EN 50264-2-1, PN-K-02511

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections available on request.