CONTROL CABLES FOR INDUSTRIAL ELECTRONIC APPLICATIONS Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

TECHNOTRONIK LiYwYw 105°C are heat resistant control cables intended for control and instrumentation circuits, for signal, monitoring and data processing systems and for analogue or digital data transmission, all for industrial electronic applications.

The cable can be applied at higher operating temperatures up to 105°C due to insulation and sheath made of special heat resistant PVC.

The cables are designed to offer high flexibility and small outer diameter combined with tensile strength.

The cables can also be used for power supply to small auxiliary devices on condition that current-carrying capacity limit (see our Technical Guide) is not exceeded.

The cables are suitable for indoor installations connecting fixed and movable equipment.

Cable outer sheath is oil-resistant.

CONSTRUCTION                                                                                                           

-    flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

-    heat resistant PVC insulation, identification colour code in accordance with DIN VDE 47100,

-    insulated conductors laid-up into a cable core,

-    special heat resistant PVC cable sheath, grey (RAL 7001), other colours also available.

CHARACTERISTICS

Conductor cross-section

mm2

0.14

0.22

0.35

0.5

0.75

1.0

1.5

Operating voltage, peak value

V

350

350

350

500

500

500

500

Voltage test

V rms

1200

1200

1200

1500

1500

1500

1500

DC conductor resistance at 20°C, maximum

Ω/km

144.0

90.0

57.0

39.0

26.0

19.5

13.3

Capacitance between conductors at 1 kHz, appr.

nF/km

90

100

110

110

110

120

120

 

Operating voltage Uo/U

Insulation resistance, minimum

Inductance, approximate

Impedance, approximate

300/300 V

20 MΩ·km

0.7 mH/km

80 Ω

Operating temperature range

      for fixed installation

      for movable installation

Minimum bending radius

Cable combustibility

Combustibility tests

Reference standards

 

from - 40 to + 105°C

from   - 5 to + 90°C

7.5 x cable diameter

flame retardant

PN-EN 60332-1-2, IEC 60332-1-2

DIN VDE 0812, DIN VDE 0814

 

Other cross-sections and conductor counts available on request.