LOCAL AREA NETWORK CABLES | Technical Data sheet |
|
|
APPLICATIONS
TECHNODATA LAN-T11 kat.6 4x2x0,57 mm cables are intended for multimedia computer networks (data, sound and HDTV transmission), applied in industrial and other dedicated networks sensitive to electromagnetic interferences.
The cables are also applied in computer networks of increased binary transfer where simultaneous transmission in both directions in all 4 symmetrical circuits is used (full duplex, Gigabit Ethernet technique).
Moisture barrier is made of plastic laminated aluminium tape longitudinally applied over a cable core and bonded to polyethylene (PE) cable sheath. The cable core is filled with petro-gel to protect the cable against moisture penetration along the cable.
Sheathing polyethylene (PE) is halogen free and UV radiation and weather resistant, however, it is not self-extinguishing and flame retardant.
The cable is suitable for outdoor installations, laying in ducts and direct earth burial.
CONSTRUCTION
- annealed copper single wire conductors of diameter 0.57 mm (23 AWG),
- polyethylene (PE) insulation coloured: white-blue and blue, white-orange and orange, white-green and green, white-brown and brown,
- insulated conductors twisted into pairs,
- pairs laid-up into a cable core on cross-shaped filler,
- cable core filled-up with petro-gel and wrapped in a polyester tape,
- moisture barrier and additional cable shielding made of a plastic laminated aluminium tape and a drain wire under the tape longitudinally applied over the cable core,
- black polyethylene (PE) cable sheath.
AVAILABLE UPON REQUEST
TECHNODATA LAN-T11-FOR kat.6 4x2x0,57 mm - cables with additional covering which is then made of special oil-resistant, self-extinguishing PVC of higher oxygen index. Cables are dedicated for indoor installations and in locations where oil-resistant and flame retardant is required.
CHARACTERISTICS
Characteristic impedance 100 ± 15 Ω
Mutual capacitance of any pair at 1 kHz, approximate 50 nF/km
Capacitance unbalance of anypair to ground at 1 kHz, max. 1600 pF/km
Insulation resistance, minimum 5000 MΩ∙km
Operating voltage 150 V
Voltage test 700 V rms
Velocity of propagation 65 %
Return loss, minimum at f=4-10 MHz 20+5 lg(f)dB
Return loss, minimum at f=10-20 MHz 25 dB
Return loss, minimum at f=20-100 MHz 20-7 lg(f/20)dB
Minimum shieldingattenuation at the frequency f=30-250 MHz 40 dB
Shielding impedanceat 10 MHz, maximum 100 mΩ/m
DC loop resistance at 20°C, maximum 188 Ω/km
Resistance unbalance of any pair of conductors, max. 2 %
Phase delay dispersionof symmetrical circuits 45 ns/100 m
Phase delay T 534+36/Öf ns/100 m
Operating temperature range
during operation from - 40 to + 70°C
during installation from -10 to + 50°C
Minimum bending radius 15 x cable diameter
Reference standards PN-EN 50288-5-1, IEC 61156-5, ISO/IEC 11801, TIA/EIA 568 A
Frequency |
Attenuation loss, maximum dB/100m |
Near end cross-talk between pairs, minimum dB |
Far end cross-talk between pairs, minimum |
|||
NEXT |
PSNEXT |
ACR |
ELFEXT |
PSELFEXT |
||
1 |
2.1 |
66.0 |
64.0 |
64.0 |
66.0 |
64.0 |
4 |
3.8 |
65.3 |
63.3 |
61.0 |
58.0 |
55.0 |
10 |
6.0 |
59.3 |
57.3 |
53.0 |
50.0 |
47.0 |
16 |
7.6 |
56.2 |
54.2 |
49.0 |
45.9 |
43.0 |
20 |
8.5 |
54.8 |
52.8 |
41.3 |
44.0 |
41.0 |
31.25 |
10.8 |
51.9 |
49.9 |
41.0 |
40.1 |
37.1 |
62.50 |
15.5 |
47.4 |
45.4 |
32.0 |
34.1 |
31.1 |
100 |
19.9 |
44.3 |
42.3 |
24.0 |
30.0 |
27.0 |
155 |
25.3 |
41.4 |
39.4 |
16.0 |
26.2 |
23.2 |
200 |
29.1 |
39.8 |
37.8 |
11.0 |
24.0 |
21.0 |
250 |
33.0 |
38.3 |
36.3 |
5.0 |
22.0 |
19.0 |
The cable meets requirements of the low voltage directive 2014/35/EU