LOCAL AREA NETWORK CABLES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

TECHNODATA LAN-UT11 kat.5e 4x2x0,5 mm cables are intended for multimedia computer networks (data, sound and HDTV transmission), applied in industrial and other dedicated networks not sensitive to electromagnetic interferences.

The cable core is filled with petro-gel to protect the cable against moisture penetration along the cable.

Sheathing polyethylene (PE) is halogen free and UV radiation and weather resistant, however, it is not self-extinguishing and flame retardant.

The cables are suitable for outdoor installations.

CONSTRUCTION

- annealed copper single wire conductors of diameter 0.51 mm, 24 AWG,

- polyethylene (PE) insulation coloured: white-blue and blue, white-orange and orange, white-green and green, white-brown and brown,

- insulated conductors twisted into pairs,

- pairs laid-up into a cable core,

- cable core filled-up with petro-gel and wrapped in a polyester tape,

- black polyethylene (PE) cable sheath.

AVAILABLE UPON REQUEST

TECHNODATA LAN-UT11n kat.5e 4x2x0,5 mm - cable intended for suspension on poles. The cable is integrated with a steel rope by an 8 shape polyethylene (PE) common sheath.

 

CHARACTERISTICS

Characteristic impedance          100 ± 15 Ω

Mutual capacitance of any pair at 1 kHz, approximate              50 nF/km

Capacitance unbalance of anypair to ground at 1 kHz,  max.      1600 pF/km

Insulation resistance, minimum          5 GΩ∙km

Operating voltage    150 V

Voltage test    700 V rms

Velocity of propagation           65 %

Return loss, minimum at f=1-20 MHz         23 dB

Return loss, minimum at f=20-100 MHz     23-10lg(f/20)dB

DC loop resistance at 20°C, maximum        188 Ω/km

Resistance unbalance of any pair of conductors, max.         3 %

Operating temperature range

      during operation                        from - 40 to + 70°C
      during installation                      from  -10 to + 50°C

Minimum bending radius                 15 x cable diameter

Reference standards                      PN-EN 50288-3-1, IEC 61156-1, ISO/IEC 11801, TIA/EIA 568 A

 

Frequency

MHz

Attenuation loss, maximum

dB/100m

Near end cross-talk for cable length ≥ 100 mminimum

dB

1

2.1

62

4

4.3

53

8

5.9

48

10

6.6

47

16

8.2

44

20

9.2

42

25

10.5

41

31.25

11.8

39

62.50

17.1

35

100

22.0

32

 The cable meets requirements of the low voltage directive 2014/35/EU

TECHNOKABEL S.A. reserves the right to change specifications without prior notice.