CONTROL CABLES FOR INDUSTRIAL ELECTRONIC APPLICATIONS | Technical Data sheet |
|
|
APPLICATIONS
TECHNOKONTROL YnKSLY are flame retardant control cables intended for control and instrumentation circuits, for signal, monitoring and data processing systems and for analogue or digital data transmission, all for industrial electronic applications.
The cable sheath is then made of special self-extinguishing PVC of high oxygen index and pass combustibility test according to PN-EN 60332-3 standard.
The cables can also be used for power supply to small auxiliary devices on condition that current-carrying capacity limit (see our Technical Guide) is not exceeded.
The cables are suitable for indoor installations connecting fixed and movable equipment.
Cable outer sheath is oil-resistant.
CONSTRUCTION
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,
- PVC insulation - identification colour code in accordance with DIN VDE 47100,
- insulated conductors laid-up in layers,
- cable core wrapped in polyester tape,
- black (RAL 9005) special self-extinguishing PVC cable sheath, other colours also available.
AVAILABLE UPON REQUEST
TECHNOKONTROL YnKSLY-Nr - cables with black conductor insulation and white conductor numbers printed on it for identification, available for cross-section 0.5 mm2 and bigger.
TECHNOKONTROL YnKSLY-O - cables designed for frequent contact with petroleum products, as in petrol stations and stores, where engine fuels and lubricants are pumped or handled. The cable sheath is then made of special PVC compound meeting oil resistance requirements of Polish standard PN-EN 60811-404.
TECHNOKONTROL YnvKSLY - cables with enhanced PVC sheath, suitable for outdoor installation and direct earth burial.
TECHNOKONTROL HKSLH - halogen free cables, applied when higher safety in case of fire is required. The cables are flame retardant, their smoke emission in fire is low and released gases are not corrosive.
TECHNOKONTROL IB-YnKSLY - specially designed intrinsically safe cable.
CHARACTERISTICS
Conductor cross-section |
mm2 |
0.35 |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
Operating voltage, peak value |
V |
350 |
500 |
500 |
500 |
500 |
500 |
Voltage test |
V rms |
1200 |
1500 |
1500 |
1500 |
1500 |
1500 |
DC conductor resistance at 20°C, maximum |
Ω/km |
55.4 |
39.0 |
26.0 |
19.5 |
13.3 |
7.98 |
Capacitance between conductors at 1 kHz, appr. |
nF/km |
100 |
100 |
120 |
120 |
130 |
130 |
Operating voltage Uo/U Insulation resistance, minimum Inductance, approximate Impedance, approximate |
300/300 V 20 MΩ·km 0.7 mH/km 80 Ω |
Operating temperature range for fixed installation for movable installation Minimum bending radius Cable combustibility Combustibility tests Reference standards |
from - 30 to + 80°C from - 5 to + 70°C 7.5 x cable diameter flame retardant PN-EN 60332-1-2, IEC 60332-1-2 PN-EN 60332-3-24, IEC 60332-3-24 (cat. C), WT-TK-14 |
The cable meets requirements of the low voltage directive 2014/35/EU
Other cross-sections and conductor counts available on request.