FLAT TELECOMMUNICATION FLEXIBLE WIRES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

YTLY are wires intended for fixed connections inside the telecommunication devices and for satellite antennas control.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request),

- PVC insulation - identification colour code according to PN-91/E-90206,

- insulated conductors laid-up in a cable core,

- PVC cable sheath, white RAL 9010, other colours also available.

AVAILABLE UPON REQUEST

11YTLY – polyurethane sheathed wires of enhanced protection against mechanical damage, particularly to abrasion and tear, also resistant to bacteria and ultraviolet radiation.

CHARACTERISTICS

Conductor cross-section

mm2

0.22

0.35

0.50

0.75

DC conductor resistance at 20°C, maximum

Ω/km

92.5

60.7

40.3

26.9

Voltage test

- AC voltage for 60s

- DC voltage

 

V rms

V

 

1000

1500

 

1500

2250

 

1500

2250

 

1500

2250

Operating voltage

Insulation resistance, minimum

 

150 V

200 MΩ·km

 

Operating temperature range

      during operation

      during installation

Minimum bending radius

Cable combustibility

Combustibility tests

Reference standards

 

from - 30 to + 70°C

from   - 5 to + 50°C

15 x cable diameter

flame retardant

PN-EN 60332-1-2, IEC 60332-1-2

PN-92/T-90200, PN-92/T-90203,  PN‑91/T90206

 

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and conductor counts available on request.