LOCAL AREA NETWORK CABLES Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

TECHNODATA LAN-T10 kat.5 1x2x0,34c mm2 cables are intended for multimedia computer networks (data, sound and HDTV transmission), applied in industrial and other dedicated networks sensitive to electromagnetic interferences.

Moisture barrier is made of plastic laminated aluminium tape longitudinally applied over a cable core and bonded to polyethylene (PE) cable sheath. The cable core is filled with petro-gel to protect the cable against moisture penetration along the cable.

Sheathing polyethylene (PE) is halogen free and UV radiation and weather resistant, however, it is not self-extinguishing and flame retardant.

The cable is suitable for outdoor installations, laying in ducts and direct earth burial.

CONSTRUCTION

- flexible, multiwire conductors, stranded of annealed tin-plated copper wires, cross-section 0.34 mm2, (7x0.25 mm),

- foam-skin polyethylene (PE) insulation coloured: yellow and black,

- insulated conductors twisted into a pair,

- pair shield incorporating an aluminium-polyester tape under a tinned copper wire braid of coverage bigger than 80%,

­- moisture barrier and additional cable shielding made of a plastic laminated aluminium tape longitudinally applied over the cable core,

- black polyethylene (PE) cable sheath.

AVAILABLE UPON REQUEST

TECHNODATA LAN-T10n kat.5 1x2x0,34c mm2 - cable intended for suspension on poles. The cable is integrated with a steel rope by an 8 shape polyethylene (PE) common sheath.

TECHNODATA LAN- T10-FOR kat.5 1x2x0,34c mm2 - cables with additional covering which is then made of special oil-resistant, self-extinguishing PVC of higher oxygen index. Cables are dedicated for indoor installations and in locations where oil-resistant and flame retardant is required.

CHARACTERISTICS

Characteristic impedance          100 ± 15 Ω

Mutual capacitance of any pair at 1 kHz, approximate              30 nF/km

Capacitance unbalance of anypair to ground at 1 kHz,  max.      1600 pF/km

Insulation resistance, minimum          150 MΩ∙km

Operating voltage    150 V

Voltage test    700 V rms

Velocity of propagation           65 %

Return loss, minimum at f=1-20 MHz         23 dB

Return loss, minimumat f=20-100 MHz         23-10lg(f/20) dB

Minimum shielding attenuation at the frequencyf=1-200 MHz        75 dB

Transfer impedanceat 10 MHz, maximum       10 mΩ/m

DC loop resistance at 20°C, maximum        114 Ω/km

Resistance unbalance of any pair of conductors, max.        3 %

Operating temperature range

      during operation                        from - 40 to + 70°C
      during installation                      from  -10 to + 50°C

Minimum bending radius                 12 x cable diameter

Reference standards                      PN-EN 50288-2-2, IEC 61156-1, ISO/IEC 11801, TIA/EIA 568 A

Frequency
MHz

Attenuation loss, maximum

dB/100m

Near end cross-talk for cable length ≥ 100 m minimum

dB

4

2.4

53

10

4.0

47

16

4.9

44

20

5.4

42

31.25

7.6

39

62.50

10.8

35

100

13.0

32

 

The cable meets requirements of the low voltage directive 2014/35/EU