FLAT LIFT CABLESS Technical Data sheet
 

 

 acrobat reader_50x50  

APPLICATIONS

H05VVH6-F nx4G… are flexible power and control cables designed for trolley systems, transport lines, machine tools, especially on hosting devices, lift, crane worked in dry and wet locations.

The cables are designed to offer high flexibility combined with tensile strength.

Cable outer sheath is oil-resistant.

The cables are suitable for connecting fixed and movable equipment in dry or wet locations.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

- black PVC insulation and white conductor numbers printed on it for identification, green-yellow protective conductor located in the quad near the axis of the cable,

- insulated conductors twisted into quads,

- quads of insulated conductors laid parallel side by side along the cable,

- black PVC cable sheath, other colours also available.

CHARACTERISTICS

Conductor cross-section

mm2

0.75

1

DC conductor resistance at 20°C, maximum

Ω/km

26.0

19.5

DC insulation resistance at 70°C, minimum

MΩ·km

0.009

0.012

 

Operating voltage Uo/U    300/500 V
Voltage test    2000 V rms
Maximum length of the free suspension    35 m
Maximum speed movement    1.6 m/s

Conductor temperature limit
      in work conditions            + 70°C
      at short-circuit                 + 160°C

Operating temperature range
      for fixed equipment             from - 40 to + 70°C
      for movable equipment        from - 20 to + 70°C

Minimum bending radius           10 x cable height

Cable combustibility                 flame retardant

Combustibility tests                 PN-EN 60332-1-2, IEC 60332-1-2

Reference standards               PN-EN 50214

 

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and conductor counts available on request.