FLAT LIFT CABLESS | Technical Data sheet |
|
|
APPLICATIONS
H05VVH6-F nx4G… are flexible power and control cables designed for trolley systems, transport lines, machine tools, especially on hosting devices, lift, crane worked in dry and wet locations.
The cables are designed to offer high flexibility combined with tensile strength.
Cable outer sheath is oil-resistant.
The cables are suitable for connecting fixed and movable equipment in dry or wet locations.
CONSTRUCTION
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,
- black PVC insulation and white conductor numbers printed on it for identification, green-yellow protective conductor located in the quad near the axis of the cable,
- insulated conductors twisted into quads,
- quads of insulated conductors laid parallel side by side along the cable,
- black PVC cable sheath, other colours also available.
CHARACTERISTICS
Conductor cross-section |
mm2 |
0.75 |
1 |
DC conductor resistance at 20°C, maximum |
Ω/km |
26.0 |
19.5 |
DC insulation resistance at 70°C, minimum |
MΩ·km |
0.009 |
0.012 |
Operating voltage Uo/U 300/500 V
Voltage test 2000 V rms
Maximum length of the free suspension 35 m
Maximum speed movement 1.6 m/s
Conductor temperature limit
in work conditions + 70°C
at short-circuit + 160°C
Operating temperature range
for fixed equipment from - 40 to + 70°C
for movable equipment from - 20 to + 70°C
Minimum bending radius 10 x cable height
Cable combustibility flame retardant
Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards PN-EN 50214
The cable meets requirements of the low voltage directive 2014/35/EU
Other cross-sections and conductor counts available on request.