COAXIAL CABLES |
Technical Data sheet |
APPLICATIONS:
- CABLES FOR TV ANTENNAS ( Z = 75 Ω ):
YWD 75-0.5/2.9
YWD and XWD 75-0.59/3.7; YWD 75 (T1) 0.59/3.7
RG 59; RG 59 B/U; RG 59 L1/U
YWDek 75-0.59/3.7
YWL and XWL 75-0.63/3.7; YWL 75 (T1) 0.63/3.7
59 F 75-0.8/3.8
YWDek and XWDek 75-0.75/4.8
- CABLES FOR SATELLITE ANTENNAS AND CABLE TELEVISION
( Z = 75 Ω ):
YWDXpek (T1) 75-1.0/4.8 (optical coverage of braid > 77%)
YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8
11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25
- CABLES FOR COMPUTER NETWORKS:
Z = 50 Ω:
RG 58; RG 58 (3) C/U
TRIAX 58 A/U
RG 213/U
YWLek 50-2.25/7.25
Z = 93 Ω: RG 62 and RG 71
Z = 125 Ω: RG 63
- CABLES FOR ELECTRONIC EQUIPMENT:
Z = 50 Ω: YWL 50-0.45/1.3; RG 174; YWLXpek 50 1.35/3.6
Z = 75 Ω: 2YCCY 75 0.4/2.5; YWLXpek and XWLXpek 75-0.45/2.0
- CABLES FOR RADIO COMMUNICATION ANTENNAS ( Z = 50 Ω ):
RG 58
RG 213/U
YWLXek 50-2.25/7.25
- CABLES FOR INDUSTRIAL TELEVISION (CCTV) ( Z = 75 Ω ):
RG 59; RG 59 B/U; RG 59 L1/U
YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8
11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25
APPLIED ABBREVIATIONS
Fe-Cu : copper-clad steel Cu-Sn : tined copper PVC : polyvinyl chloride |
PE : polyethylene Al/PETP : aluminium/polyester (2 layers) tape Al/PETP/Al. : aluminium/polyester/aluminium (3 layers) tape AL/Cop : copolymer coated aluminium tape |
AVAILABLE OPTIONS ( AVAILABLE UPON REQUEST ) Halogen free cables are also available (RG-H; HWD; HWL,…). |
|
|
|
|
|
Cable name |
YWL 50 0,45/1,3 |
RG 174 |
RG 58 |
TRIAX 58 A/U |
Product No. |
0259 004 |
0221 023 |
0221 012 |
0611 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
FeCu |
CuSn |
CuSn |
number and diameter of wires [mm] |
7x0,15 |
7x0,16 |
19x0,18 |
7x0,32 |
diameter [mm] |
0,45 |
0,48 |
0,9 |
0,96 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
1,3 |
1,52 |
3,0 |
3,0 |
Outer conductor: |
||||
material and CONSTRUCTION |
braid Cu |
braid Cu (86%) |
braid Cu |
braid Cu PE insulation, 4,45 mm braid CuSn |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black and white |
black and white |
yellow |
Diameter Outer [mm] |
2,7 |
2,8 |
4,95 |
6,1 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
50 ± 2 |
50 ± 2 |
50 ± 2 |
50 ± 2 |
Capacitance [pF/m] przy f=1 kHz |
97,8 |
100 |
103 |
100 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
152 |
317 |
32,5 |
31 |
outer conductor |
45,3 |
43 |
13,4 |
15,5/14,1 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
21,3 |
19,0 |
10,5 |
10,8 |
100 |
30,4 |
30,0 |
15,4 |
16,1 |
200 |
43,1 |
45,0 |
22,6 |
|
800 |
90,0 |
84,0 |
50,1 |
|
1000 |
101,7 |
92,0 |
58,3 |
78,7 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
MIL-C-17 |
MIL-C-17/119 G |
MIL-C-17/28 |
DT 22/06/03 |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
15 |
15 |
25 |
50 |
Weight [kg/km] |
11,5 |
12,0 |
40,0 |
61,0 |
|
|
|
|
Cable name |
YWLXpek 50 1,35/3,6 |
YWLek 50 2,25/7,25 |
RG 213/U |
Product No. |
0264 001 |
0261 002 |
0221 018 |
CONSTRUCTION |
|||
Inner conductor: |
|||
material |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
7x0,45 |
7x0,75 |
7x0,75 |
diameter [mm] |
1,35 |
2,25 |
2,25 |
Insulation: |
|||
material |
PE - piankowy |
PE |
PE |
diameter [mm] |
3,6 |
7,3 |
7,3 |
Outer conductor: |
|||
material and CONSTRUCTION |
taśma Al/PETP braid CuSn |
taśma Al/PETP/Al braid CuSn |
braid Cu |
Sheath: |
|||
material |
PVC |
PVC |
PVC |
colour |
black and white |
black and white |
black |
Diameter Outer [mm] |
5,3 |
10,1 |
10,2 |
ELECTRICAL PARAMETERS AT 20°C |
|||
Characteristic impedance [Ω] |
50 ± 2 |
50 ± 2 |
50 ± 2 |
Capacitance [pF/m] przy f=1 kHz |
87 |
100 |
100 |
Velocity of propagation [%] |
78 |
66 |
66 |
DC resistance [mΩ/m]: |
|||
inner conductor |
17,0 |
5,7 |
5,7 |
outer conductor |
15,0 |
12,7 |
5,8 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||
50 |
7,4 |
3,9 |
4,5 |
100 |
10,0 |
5,4 |
6,5 |
200 |
14,0 |
7,9 |
9,4 |
800 |
29,0 |
18,4 |
21,7 |
1000 |
33,0 |
21,1 |
21,1 |
2400 |
54,0 |
38,5 |
46,1 |
Return loss [dB] - min. |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
60 |
40 |
OTHERS DATA |
|||
Reference standards |
DT 68/04/05 |
IEC 60096-2A,PN-EN 50117 |
MIL-C-17/74 C |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
50 |
70 |
70 |
Weight [kg/km] |
38,5 |
130 |
154 |
|
|
|
|
||
Cable name |
2YCCY 75 0,4/2,5 |
YWD 75 0,5/2,9 |
YWD 75 0,59/3,7 |
XWD 75 0,59/3,7 |
|
Product No. |
0255 003 |
0253 002 |
0253 003 |
0254 003 |
|
CONSTRUCTION |
|||||
Inner conductor: |
|||||
material |
Fe-Cu |
Cu |
Cu |
Cu |
|
number and diameter of wires [mm] |
1x0,0,4 |
1x0,5 |
1x0,59 |
1x0,59 |
|
diameter [mm] |
0,4 |
0,5 |
0,59 |
0,59 |
|
Insulation: |
|||||
material |
PE |
PE |
PE |
PE |
|
diameter [mm] |
2,5 |
2,9 |
3,7 |
3,7 |
|
Outer conductor: |
|||||
material and CONSTRUCTION |
braid CuSn tape separator braid CuSn |
braid Cu |
braid Cu |
braid Cu |
|
Sheath: |
|||||
material |
PVC |
PVC |
PVC |
PE |
|
colour |
olive with yellow stripe |
white |
black and white |
black |
|
Diameter Outer [mm] |
4,5 |
5 |
5,5 |
5,5 |
|
ELECTRICAL PARAMETERS AT 20°C |
|||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 5 |
75 ± 3 |
75 ± 3 |
|
Capacitance [pF/m] przy f=1 kHz |
70 |
69,6 |
67 |
67 |
|
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
|
DC resistance [mΩ/m]: |
|||||
inner conductor |
360 |
86,2 |
63 |
63 |
|
outer conductor |
24/24 |
57,6 |
27,2 |
27,2 |
|
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||||
50 |
11,5 |
9,7 |
8,4 |
8,4 |
|
100 |
16 |
15 |
13,8 |
13,8 |
|
200 |
23 |
22,9 |
18,5 |
18,5 |
|
800 |
50,2 |
36 |
36 |
||
1000 |
54 |
40,9 |
40,9 |
||
2400 |
68,5 |
68,5 |
|||
Return loss [dB] - min. |
26 |
20 |
20 |
20 |
|
Shielding attenuation [dB] - min. |
50 |
40 |
40 |
40 |
|
OTHERS DATA |
|||||
Reference standards |
DT 6/07/01 |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
|
PN-EN 50117 |
PN-EN 50117 |
PN-EN 50117 |
|||
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
|
Minimum bending radius [mm] |
25 |
30 |
30 |
35 |
|
Weight [kg/km] |
31 |
29 |
34 |
43 |
|
|
|
|
|
Cable name |
YWD 75 (T1) 0,59/3,7 |
RG 59 |
RG 59 L1/U |
RG 59 B/U |
Product No. |
0253 010 |
0221 002 |
0221 022 |
0221 008 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Fe-Cu |
Fe-Cu |
Cu |
number and diameter of wires [mm] |
1x0,59 |
1x0,59 |
1x0,59 |
1x0,59 |
diameter [mm] |
0,59 |
0,59 |
0,59 |
0,59 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
3,7 |
3,7 |
3,7 |
3,7 |
Outer conductor: |
||||
material and CONSTRUCTION |
braid Cu |
braid Cu |
braid Cu |
braid Cu |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black |
black |
black and white |
Diameter Outer [mm] |
5,9 |
6,15 |
6,15 |
6,15 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,0 |
67,0 |
67,0 |
67,0 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
63,0 |
157,5 |
157,5 |
63,0 |
outer conductor |
16,3 |
8,0 |
16,3 |
8,0 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
7,4 |
7,7 |
9,0 |
7,7 |
100 |
10,7 |
11,3 |
13,7 |
11,1 |
200 |
15,5 |
16,5 |
18,2 |
16,2 |
800 |
33,7 |
35,6 |
36,3 |
35,6 |
1000 |
38,1 |
40,5 |
41,5 |
40,5 |
2400 |
55,4 |
59,5 |
65,0 |
59,5 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
40 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
MIL-C-17/29C |
MIL-C-17 |
MIL-C-17/29C |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
35 |
35 |
35 |
35 |
Weight [kg/km] |
43 |
56 |
45 |
56 |
|
|
|
|
|
Cable name |
YWDek 75 0,59/3,7 |
YWL 75 0,63/3,7 |
YWL 75 (T1) 0,63/3,7 |
XWL 75 0,63/3,7 |
Product No. |
0254 002 |
0259 001 |
0259 010 |
0259 006 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x0,59 |
7x0,2 |
7x0,2 |
7x0,2 |
diameter [mm] |
0,59 |
0,6 |
0,6 |
0,6 |
Insulation: |
||||
material |
PE |
PE |
PE |
PE |
diameter [mm] |
3,7 |
3,7 |
3,7 |
3,7 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP tape |
braid Cu |
braid Cu |
braid Cu |
Sheath: |
||||
material |
PVC |
PVC |
PVC |
PE |
colour |
black and white |
black and white |
black and white |
black and white |
Diameter Outer [mm] |
5,8 |
5,5 |
5,9 |
5,5 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,4 |
64,7 |
64,7 |
64,7 |
Velocity of propagation [%] |
66 |
66 |
66 |
66 |
DC resistance [mΩ/m]: |
||||
inner conductor |
63,0 |
84,2 |
84,2 |
84,2 |
outer conductor |
33,6 |
27,2 |
16,3 |
16,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
7,2 |
8,4 |
7,9 |
8,4 |
100 |
10,1 |
11,7 |
11,2 |
11,7 |
200 |
14,7 |
16,8 |
16,3 |
16,8 |
800 |
33,0 |
36,0 |
34,7 |
36,0 |
1000 |
38,1 |
40,9 |
39,1 |
40,9 |
2400 |
57,2 |
68,5 |
64,4 |
68,5 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
35 |
30 |
30 |
35 |
Weight [kg/km] |
35 |
33 |
43 |
30 |
|
|
|
|
|
Cable name |
YWDek 75 0,75/4,8 |
XWDek 75 0,75/4,8 |
YWLXpek 75 0,45/2,0 |
59 F 75 0,8/3,8 |
Product No. |
0254 008 |
0254 007 |
0263 002 |
0001 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x0,75 |
1x0,75 |
7x0,15 |
1x0,8 |
diameter [mm] |
0,75 |
0,75 |
0,45 |
0,8 |
Insulation: |
||||
material |
PE |
PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
4,8 |
4,8 |
2,0 |
3,8 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
||||
material |
PVC |
PE |
PVC |
PE |
colour |
black and white |
black |
black and white |
black and white |
Diameter Outer [mm] |
7,3 |
7,3 |
3,6 |
6,0 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
67,1 |
67,1 |
60,6 |
55,7 |
Velocity of propagation [%] |
66 |
66 |
78 |
78 |
DC resistance [mΩ/m]: |
||||
inner conductor |
38,7 |
38,7 |
176,0 |
35,6 |
outer conductor |
13,0 |
13,0 |
16,6 |
23,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
5,8 |
5,8 |
11,8 |
6,0 |
100 |
8,4 |
8,4 |
16,9 |
8,3 |
200 |
11,7 |
11,7 |
24,4 |
11,8 |
800 |
26,5 |
26,5 |
49,6 |
25,8 |
1000 |
30,3 |
30,3 |
55,7 |
29,2 |
2400 |
50,9 |
50,9 |
46,2 |
|
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
40 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-40 ¸ +70 |
-20 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
45 |
48 |
18 |
40 |
Weight [kg/km] |
64,5 |
64,5 |
17,5 |
37 |
|
|
|
|
|
Cable name |
YWDXpek (T1) 75 1,0/4,8 |
YWDXpek 75 1,0/4,8 |
XWDXpek 75 1,0/4,8 |
RG 6 L1/U |
Product No. |
0258 013 |
0258 010 |
0258 005 |
0221 021 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Cu |
Cu |
Cu |
number and diameter of wires [mm] |
1x1,0 |
1x1,0 |
1x1,0 |
1x1,0 |
diameter [mm] |
1,0 |
1,0 |
1,0 |
1,0 |
Insulation: |
||||
material |
foam-skin PE |
foam-skin PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
4,8 |
4,8 |
4,8 |
4,8 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
||||
material |
PVC |
PVC |
PE |
PVC |
colour |
black and white |
black and white |
black |
black and white |
Diameter Outer [mm] |
7,3 |
7,3 |
3,6 |
6,0 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
75 ± 3 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
57,0 |
57,0 |
57,0 |
57,0 |
Velocity of propagation [%] |
78 |
78 |
78 |
78 |
DC resistance [mΩ/m]: |
||||
inner conductor |
22,0 |
22,0 |
22,0 |
22,0 |
outer conductor |
8,0 |
20,0 |
20,0 |
21,0 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
4,6 |
6,0 |
6,0 |
6,0 |
100 |
6,4 |
8,3 |
8,3 |
8,3 |
200 |
9,1 |
11,8 |
11,8 |
11,8 |
800 |
20,2 |
25,8 |
25,8 |
25,8 |
1000 |
22,0 |
29,2 |
29,2 |
29,2 |
2400 |
38,5 |
46,2 |
46,2 |
46,2 |
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
75 |
75 |
75 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
-20 ¸ +70 |
Minimum bending radius [mm] |
45 |
45 |
60 |
45 |
Weight [kg/km] |
57 |
43 |
37 |
45 |
|
|
|
|
|
Cable name |
11F 75 1,63/7,25 |
RG 62 |
RG 71 |
RG 63 |
Product No. |
0001 002 |
0221 003 |
0221 005 |
0221 001 |
CONSTRUCTION |
||||
Inner conductor: |
||||
material |
Cu |
Fe-Cu |
Fe-Cu |
Fe-Cu |
number and diameter of wires [mm] |
1x1,63 |
1x0,64 |
1x0,64 |
1x0,64 |
diameter [mm] |
1,0 |
0,64 |
0,64 |
0,64 |
Insulation: |
||||
material |
foam-skin PE |
PE- air |
PE- air |
PE- air |
diameter [mm] |
7,25 |
3,7 |
3,7 |
7,2 |
Outer conductor: |
||||
material and CONSTRUCTION |
Al/PETP/Al |
braid Cu |
braid Cu |
|
Sheath: |
||||
material |
PVC |
PVC |
PE |
PVC |
colour |
black and white |
black |
black |
black and white |
Diameter Outer [mm] |
10,0 |
6,15 |
6,2 |
10,4 |
ELECTRICAL PARAMETERS AT 20°C |
||||
Characteristic impedance [Ω] |
75 ± 3 |
93 ± 5 |
93 ± 5 |
125 ± 6 |
Capacitance [pF/m] przy f=1 kHz |
57,0 |
44,5 |
43,4 |
33,1 |
Velocity of propagation [%] |
78 |
83 |
83 |
84 |
DC resistance [mΩ/m]: |
||||
inner conductor |
8,0 |
138,8 |
138,8 |
138,8 |
outer conductor |
14,5 |
8,0 |
4,5 |
3,3 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
||||
50 |
3,1 |
6,3 |
6,5 |
4,3 |
100 |
4,4 |
9,2 |
9,3 |
6,2 |
200 |
6,4 |
12,6 |
13,3 |
8,8 |
800 |
14,0 |
26,1 |
28,1 |
18,1 |
1000 |
16,0 |
30,8 |
31,8 |
20,4 |
2400 |
29,4 |
|||
Return loss [dB] - min. |
20 |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
40 |
50 |
40 |
OTHERS DATA |
||||
Reference standards |
IEC 60096-2A |
MIL-C-17/30D |
MIL-C-17/90A |
MIL-C-17/30D |
Operating temperature range [°C] |
-20 ¸ +70 |
-20 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
60 |
35 |
35 |
110 |
Weight [kg/km] |
93 |
56 |
57 |
125 |
|
|
|
|
Cable name |
RG 58 (3) C/U |
XzWDXpekw 75 1,0/4,8 |
11F (3) 75 1,63/7,25 |
Product No. |
0221 013 |
0276 002 |
0001 004 |
CONSTRUCTION |
|||
Inner conductor: |
|||
material |
CuSn |
Cu |
Cu |
number and diameter of wires [mm] |
19x0,18 |
1x1,0 |
1x1,63 |
diameter [mm] |
0,9 |
1,0 |
1,63 |
Insulation: |
|||
material |
PE |
foam-skin PE |
foam-skin PE |
diameter [mm] |
2,95 |
4,8 |
7,25 |
Outer conductor: |
|||
material and CONSTRUCTION |
braid CuSn |
Al/PETP/Al tape |
Al/PETP/Al tape |
Sheath: |
|||
material |
gel |
gel |
gel |
colour |
black |
black |
black |
Diameter Outer [mm] |
6,8 |
8,4 |
11,5 |
ELECTRICAL PARAMETERS AT 20°C |
|||
Characteristic impedance [Ω] |
50 ± 2 |
75 ± 3 |
75 ± 3 |
Capacitance [pF/m] przy f=1 kHz |
103,0 |
60,0 |
60,0 |
Velocity of propagation [%] |
66 |
78 |
78 |
DC resistance [mΩ/m]: |
|||
inner conductor |
32,5 |
22,0 |
8,0 |
outer conductor |
13,4 |
9,2 |
8,5 |
Attenuation [dB/100 m] – average, at frequency [MHz]: |
|||
50 |
11,4 |
4,6 |
3,1 |
100 |
16,6 |
6,4 |
4,4 |
200 |
24,4 |
9,1 |
6,4 |
800 |
73,0 |
20,2 |
14,4 |
1000 |
87,0 |
22,0 |
16,7 |
2400 |
38,5 |
31,0 |
|
Return loss [dB] - min. |
20 |
20 |
20 |
Shielding attenuation [dB] - min. |
75 |
75 |
75 |
OTHERS DATA |
|||
Reference standards |
MIL-C-17 |
IEC 60096-2A |
IEC 60096-2A |
Operating temperature range [°C] |
-40 ¸ +70 |
-40 ¸ +70 |
-40 ¸ +70 |
Minimum bending radius [mm] |
70 |
90 |
120 |
Weight [kg/km] |
58 |
74 |
111,0 |
SPECIAL CABLES PS-Y-29 |
Technical Data sheet |
|
Hybrid cables PS-Y-29 intended for operation in CCTV networks.
Cables are equipped with coax WD 75-0,59/3,7 for visual signal transmission and a group of insulated conductors for camera power supply and control signals transmission.
The cables are suitable for fixed indoor and outdoor installations.
CONSTRUCTION
coaxial cable WD 75-0,59/3,7
- soft solid copper conductor, diameter 0.59 mm,
- polyethylene (PE) insulation, diameter 3.7 mm,
- copper wire braid,
LiY wires
- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,
- PVC insulation - identification colour code in accordance with DIN VDE 47100,
- insulated conductors twisted into pair,
- pair wrapped in polyester tape,
PS-Y-29 cable
- white (RAL 9010) PVC cable sheath, (8 shape) extruded on the parallel arranged coaxial and pair of insulated conductors, other colours also available.Coaxial cable WD 75-0,59/3,7
Characteristic impedance 75 ± 3 Ω
Capacitance at 1 kHz, approximate 67 nF/km
Velocity of propagation 66 %
DC resistance at 20°C, approximate
inner conductor 63 Ω/km
outer conductor 27.2 Ω/km
LiY wires
Operating voltage Uo/U 300/300 V
Operating voltage, peak value 500 V
Voltage test 1500 V rms
DC conductor resistance at 20°C, maximum:
conductor 0.50 mm2 39.0 Ω/km
conductor 0.75 mm2 26.0 Ω/km
conductor 1.0 mm2 19.5 Ω/km
Insulation resistance, minimum 20 MΩ∙km
Inductance, approximate 0.7 mH/km
Cable PS-Y-29
Operating temperature range
during operation from - 30 to + 70°C
during installation from - 10 to + 50°C
Minimum bending radius 10 x cable diameter
Cable combustibility flame retardant
Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards
coaxial cable PN-91/T-90601, IEC 61156-1
LiY wires DIN VDE 0812
The cable meets requirements of the low voltage directive 2014/35/EU
Attenuation loss [dB/100m] average - at frequency [MHz]: |
|
1 |
1.0 |
50 |
7.4 |
100 |
10.5 |
200 |
15.1 |
300 |
18.8 |
500 |
24.8 |
800 |
32.0 |
1000 |
36.3 |
1500 |
45.6 |
2000 |
55.7 |
2400 |
56.9 |
Other cross-sections and conductor counts available on request.
TECHNOKABEL S.A. reserves the right to change specifications without prior notice.
RG 108 A/U 78Ω | Technical Data sheet |
|
Cable RG 108 A/U intended for operation in IBM cash registers.
To achieve high analogue or digital data transmission performance the cable is protected against external electromagnetic interferences by an overall shield.
The cables are suitable for indoor installations connecting fixed and movable equipment.
CONSTRUCTION
- flexible, multiwire conductors, stranded of tin-plated copper wires, cross-section 0.5mm2 (7x0.3 mm),
- polyethylene (PE) insulation - diameter 2.0 mm,
- insulated conductors twisted into pair,
- pair wrapped in polyester tape,
- tinned copper wire braid shield, density of coverage bigger than 85%,
- PVC cable sheath, colours on request.
CHARACTERISTICS
Characteristic impedance 78 ± 7 Ω
Mutual capacitanceat at 1 kHz 68 ± 5 nF/km
DC conductor resistance at 20°C, approximate 34.5 Ω/km
DC screen resistance at 20°C,approximate 18.0 Ω/km
Operating temperature range: from - 30 to + 70 °C
Minimum bending radius:
single 30 mm
multiple 90 mm
Cable combustibility flame retardant
Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards MIL-C-17/45ETIA/EIA 568 A
Attenuation loss, approximate
f |
MHz |
1 |
2 |
3 |
5 |
7 |
10 |
20 |
30 |
50 |
70 |
100 |
a |
dB/100 m |
2.5 |
3.7 |
4.6 |
6.1 |
7.2 |
8.5 |
12.1 |
14 |
17.2 |
20.2 |
26.0 |
The cable meets requirements of the low voltage directive 2014/35/EU