COAXIAL CABLES

Technical Data sheet
acrobat reader_50x50
 

APPLICATIONS:

  • CABLES FOR TV ANTENNAS ( Z = 75 Ω ):

YWD 75-0.5/2.9

YWD and XWD 75-0.59/3.7; YWD 75 (T1) 0.59/3.7

RG 59; RG 59 B/U; RG 59 L1/U

YWDek 75-0.59/3.7

YWL and XWL 75-0.63/3.7; YWL 75 (T1) 0.63/3.7

59 F 75-0.8/3.8

YWDek and XWDek 75-0.75/4.8

  • CABLES FOR SATELLITE ANTENNAS AND CABLE TELEVISION

( Z = 75 Ω ):

YWDXpek (T1) 75-1.0/4.8 (optical coverage of braid > 77%)

YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8

11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25

  • CABLES FOR COMPUTER NETWORKS:

Z = 50 Ω:

RG 58; RG 58 (3) C/U

TRIAX 58 A/U

RG 213/U

YWLek 50-2.25/7.25

Z = 93 Ω: RG 62 and RG 71

Z = 125 Ω: RG 63

  • CABLES FOR ELECTRONIC EQUIPMENT:

Z = 50 Ω: YWL 50-0.45/1.3; RG 174; YWLXpek 50 1.35/3.6

Z = 75 Ω: 2YCCY 75 0.4/2.5; YWLXpek and XWLXpek 75-0.45/2.0

  • CABLES FOR RADIO COMMUNICATION ANTENNAS ( Z = 50 Ω ):

RG 58

RG 213/U

YWLXek 50-2.25/7.25

  • CABLES FOR INDUSTRIAL TELEVISION (CCTV) ( Z = 75 Ω ):

RG 59; RG 59 B/U; RG 59 L1/U

YWDXpek and XWDXpek 75-1.0/4.8; XzWDXpekw 75-1.0/4.8

11 F 75-1.63/7.25 and 11 F 75 (3) 1.63/7.25

 

APPLIED ABBREVIATIONS


Cu : bare copper

Fe-Cu : copper-clad steel

Cu-Sn : tined copper

PVC : polyvinyl chloride

 

PE : polyethylene

Al/PETP : aluminium/polyester (2 layers) tape

Al/PETP/Al. : aluminium/polyester/aluminium (3 layers) tape

AL/Cop : copolymer coated aluminium tape

AVAILABLE OPTIONS ( AVAILABLE UPON REQUEST )

Halogen free cables are also available (RG-H; HWD; HWL,…).
Other colours on request.

 

 

 

 

 

 

 

 

 

 

 

Cable name

YWL 50 0,45/1,3

RG 174

RG 58

TRIAX 58 A/U

Product No.

0259 004

0221 023

0221 012

0611 001

         

CONSTRUCTION

Inner conductor:

material

Cu

FeCu

CuSn

CuSn

number and diameter of wires [mm]

7x0,15

7x0,16

19x0,18

7x0,32

diameter [mm]

0,45

0,48

0,9

0,96

Insulation:

material

PE

PE

PE

PE

diameter [mm]

1,3

1,52

3,0

3,0

Outer conductor:

material and CONSTRUCTION

braid Cu

braid Cu (86%)

braid Cu

braid Cu

PE insulation, 4,45 mm

braid CuSn

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black and white

black and white

yellow

Diameter Outer [mm]

2,7

2,8

4,95

6,1

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

50 ± 2

50 ± 2

50 ± 2

Capacitance [pF/m] przy f=1 kHz

97,8

100

103

100

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

152

317

32,5

31

outer conductor

45,3

43

13,4

15,5/14,1

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

21,3

19,0

10,5

10,8

100

30,4

30,0

15,4

16,1

200

43,1

45,0

22,6

 

800

90,0

84,0

50,1

 

1000

101,7

92,0

58,3

78,7

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

40

40

40

40

         

OTHERS DATA

Reference standards

MIL-C-17

MIL-C-17/119 G

MIL-C-17/28

DT 22/06/03

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

15

15

25

50

Weight [kg/km]

11,5

12,0

40,0

61,0

 

 

Cable name

YWLXpek 50 1,35/3,6

YWLek 50 2,25/7,25

RG 213/U

Product No.

0264 001

0261 002

0221 018

       

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

number and diameter of wires [mm]

7x0,45

7x0,75

7x0,75

diameter [mm]

1,35

2,25

2,25

Insulation:

material

PE - piankowy

PE

PE

diameter [mm]

3,6

7,3

7,3

Outer conductor:

material and CONSTRUCTION

taśma Al/PETP

braid CuSn

taśma Al/PETP/Al

braid CuSn

braid Cu

Sheath:

material

PVC

PVC

PVC

colour

black and white

black and white

black

Diameter Outer [mm]

5,3

10,1

10,2

       

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

50 ± 2

50 ± 2

Capacitance [pF/m] przy f=1 kHz

87

100

100

Velocity of propagation [%]

78

66

66

DC resistance [mΩ/m]:

inner conductor

17,0

5,7

5,7

outer conductor

15,0

12,7

5,8

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,4

3,9

4,5

100

10,0

5,4

6,5

200

14,0

7,9

9,4

800

29,0

18,4

21,7

1000

33,0

21,1

21,1

2400

54,0

38,5

46,1

Return loss [dB] - min.

20

20

20

Shielding attenuation [dB] - min.

40

60

40

       

OTHERS DATA

Reference standards

DT 68/04/05

IEC 60096-2A,PN-EN 50117

MIL-C-17/74 C

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

50

70

70

Weight [kg/km]

38,5

130

154

 

 

 

Cable name

2YCCY 75 0,4/2,5

YWD 75 0,5/2,9

YWD 75 0,59/3,7

XWD 75 0,59/3,7

 

Product No.

0255 003

0253 002

0253 003

0254 003

 
           

CONSTRUCTION

 

Inner conductor:

 

material

Fe-Cu

Cu

Cu

Cu

 

number and diameter of wires [mm]

1x0,0,4

1x0,5

1x0,59

1x0,59

 

diameter [mm]

0,4

0,5

0,59

0,59

 

Insulation:

 

material

PE

PE

PE

PE

 

diameter [mm]

2,5

2,9

3,7

3,7

 

Outer conductor:

 

material and CONSTRUCTION

braid CuSn

tape separator

braid CuSn

braid Cu

braid Cu

braid Cu

 

Sheath:

 

material

PVC

PVC

PVC

PE

 

colour

olive with yellow stripe

white

black and white

black

 

Diameter Outer [mm]

4,5

5

5,5

5,5

 
           

ELECTRICAL PARAMETERS AT 20°C

 

Characteristic impedance [Ω]

75 ± 3

75 ± 5

75 ± 3

75 ± 3

 

Capacitance [pF/m] przy f=1 kHz

70

69,6

67

67

 
 

Velocity of propagation [%]

66

66

66

66

 

DC resistance [mΩ/m]:

 

inner conductor

360

86,2

63

63

 

outer conductor

24/24

57,6

27,2

27,2

 

Attenuation [dB/100 m] – average, at frequency [MHz]:

   

50

11,5

9,7

8,4

8,4

 

100

16

15

13,8

13,8

 

200

23

22,9

18,5

18,5

 

800

 

50,2

36

36

 

1000

 

54

40,9

40,9

 

2400

   

68,5

68,5

 

Return loss [dB] - min.

26

20

20

20

 

Shielding attenuation [dB] - min.

50

40

40

40

 
           

OTHERS DATA

 

Reference standards

DT 6/07/01

IEC 60096-2A

IEC 60096-2A

IEC 60096-2A

 

PN-EN 50117

PN-EN 50117

PN-EN 50117

 

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

 

Minimum bending radius [mm]

25

30

30

35

 

Weight [kg/km]

31

29

34

43

 

 

 

Cable name

YWD 75 (T1) 0,59/3,7

RG 59

RG 59 L1/U

RG 59 B/U

Product No.

0253 010

0221 002

0221 022

0221 008

         

CONSTRUCTION

Inner conductor:

material

Cu

Fe-Cu

Fe-Cu

Cu

number and diameter of wires [mm]

1x0,59

1x0,59

1x0,59

1x0,59

diameter [mm]

0,59

0,59

0,59

0,59

Insulation:

material

PE

PE

PE

PE

diameter [mm]

3,7

3,7

3,7

3,7

Outer conductor:

material and CONSTRUCTION

braid Cu

braid Cu

braid Cu

braid Cu

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black

black

black and white

Diameter Outer [mm]

5,9

6,15

6,15

6,15

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,0

67,0

67,0

67,0

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

63,0

157,5

157,5

63,0

outer conductor

16,3

8,0

16,3

8,0

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,4

7,7

9,0

7,7

100

10,7

11,3

13,7

11,1

200

15,5

16,5

18,2

16,2

800

33,7

35,6

36,3

35,6

1000

38,1

40,5

41,5

40,5

2400

55,4

59,5

65,0

59,5

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

40

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

MIL-C-17/29C

MIL-C-17

MIL-C-17/29C

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

35

35

35

35

Weight [kg/km]

43

56

45

56

 

 


Cable name

YWDek 75 0,59/3,7

YWL 75 0,63/3,7

YWL 75 (T1) 0,63/3,7

XWL 75 0,63/3,7

Product No.

0254 002

0259 001

0259 010

0259 006

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x0,59

7x0,2

7x0,2

7x0,2

diameter [mm]

0,59

0,6

0,6

0,6

Insulation:

material

PE

PE

PE

PE

diameter [mm]

3,7

3,7

3,7

3,7

Outer conductor:

material and CONSTRUCTION

Al/PETP tape
braid CuSn

braid Cu

braid Cu

braid Cu

Sheath:

material

PVC

PVC

PVC

PE

colour

black and white

black and white

black and white

black and white

Diameter Outer [mm]

5,8

5,5

5,9

5,5

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,4

64,7

64,7

64,7

Velocity of propagation [%]

66

66

66

66

DC resistance [mΩ/m]:

inner conductor

63,0

84,2

84,2

84,2

outer conductor

33,6

27,2

16,3

16,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

7,2

8,4

7,9

8,4

100

10,1

11,7

11,2

11,7

200

14,7

16,8

16,3

16,8

800

33,0

36,0

34,7

36,0

1000

38,1

40,9

39,1

40,9

2400

57,2

68,5

64,4

68,5

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

35

30

30

35

Weight [kg/km]

35

33

43

30

 

 

Cable name

YWDek 75 0,75/4,8

XWDek 75 0,75/4,8

YWLXpek 75 0,45/2,0

59 F 75 0,8/3,8

Product No.

0254 008

0254 007

0263 002

0001 001

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x0,75

1x0,75

7x0,15

1x0,8

diameter [mm]

0,75

0,75

0,45

0,8

Insulation:

material

PE

PE

foam-skin PE

foam-skin PE

diameter [mm]

4,8

4,8

2,0

3,8

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Sheath:

material

PVC

PE

PVC

PE

colour

black and white

black

black and white

black and white

Diameter Outer [mm]

7,3

7,3

3,6

6,0

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

67,1

67,1

60,6

55,7

Velocity of propagation [%]

66

66

78

78

DC resistance [mΩ/m]:

inner conductor

38,7

38,7

176,0

35,6

outer conductor

13,0

13,0

16,6

23,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

5,8

5,8

11,8

6,0

100

8,4

8,4

16,9

8,3

200

11,7

11,7

24,4

11,8

800

26,5

26,5

49,6

25,8

1000

30,3

30,3

55,7

29,2

2400

50,9

50,9

 

46,2

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

40

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-40 ¸ +70

-20 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

45

48

18

40

Weight [kg/km]

64,5

64,5

17,5

37

 

 

Cable name

YWDXpek (T1) 75 1,0/4,8

YWDXpek 75 1,0/4,8

XWDXpek 75 1,0/4,8

RG 6 L1/U

Product No.

0258 013

0258 010

0258 005

0221 021

         

CONSTRUCTION

Inner conductor:

material

Cu

Cu

Cu

Cu

number and diameter of wires [mm]

1x1,0

1x1,0

1x1,0

1x1,0

diameter [mm]

1,0

1,0

1,0

1,0

Insulation:

material

foam-skin PE

foam-skin PE

foam-skin PE

foam-skin PE

diameter [mm]

4,8

4,8

4,8

4,8

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al tape
braid CuSn
density > 77%

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Al/PETP/Al tape
braid CuSn

Sheath:

material

PVC

PVC

PE

PVC

colour

black and white

black and white

black

black and white

Diameter Outer [mm]

7,3

7,3

3,6

6,0

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

75 ± 3

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

57,0

57,0

57,0

57,0

Velocity of propagation [%]

78

78

78

78

DC resistance [mΩ/m]:

inner conductor

22,0

22,0

22,0

22,0

outer conductor

8,0

20,0

20,0

21,0

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

4,6

6,0

6,0

6,0

100

6,4

8,3

8,3

8,3

200

9,1

11,8

11,8

11,8

800

20,2

25,8

25,8

25,8

1000

22,0

29,2

29,2

29,2

2400

38,5

46,2

46,2

46,2

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

75

75

75

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

-20 ¸ +70

Minimum bending radius [mm]

45

45

60

45

Weight [kg/km]

57

43

37

45

 

 

Cable name

11F 75 1,63/7,25

RG 62

RG 71

RG 63

Product No.

0001 002

0221 003

0221 005

0221 001

         

CONSTRUCTION

Inner conductor:

material

Cu

Fe-Cu

Fe-Cu

Fe-Cu

number and diameter of wires [mm]

1x1,63

1x0,64

1x0,64

1x0,64

diameter [mm]

1,0

0,64

0,64

0,64

Insulation:

material

foam-skin PE

PE- air

PE- air

PE- air

diameter [mm]

7,25

3,7

3,7

7,2

Outer conductor:

material and CONSTRUCTION

Al/PETP/Al
 tape braid CuSn

braid Cu

braid Cu
braid CuSn


braid Cu

Sheath:

material

PVC

PVC

PE

PVC

colour

black and white

black

black

black and white

Diameter Outer [mm]

10,0

6,15

6,2

10,4

         

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

75 ± 3

93 ± 5

93 ± 5

125 ± 6

Capacitance [pF/m] przy f=1 kHz

57,0

44,5

43,4

33,1

Velocity of propagation [%]

78

83

83

84

DC resistance [mΩ/m]:

inner conductor

8,0

138,8

138,8

138,8

outer conductor

14,5

8,0

4,5

3,3

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

3,1

6,3

6,5

4,3

100

4,4

9,2

9,3

6,2

200

6,4

12,6

13,3

8,8

800

14,0

26,1

28,1

18,1

1000

16,0

30,8

31,8

20,4

2400

29,4

     

Return loss [dB] - min.

20

20

20

20

Shielding attenuation [dB] - min.

75

40

50

40

         

OTHERS DATA

Reference standards

IEC 60096-2A
PN-EN 50117

MIL-C-17/30D

MIL-C-17/90A

MIL-C-17/30D

Operating temperature range [°C]

-20 ¸ +70

-20 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

60

35

35

110

Weight [kg/km]

93

56

57

125

 

 

Cable name

RG 58 (3) C/U

XzWDXpekw 75 1,0/4,8

11F (3) 75 1,63/7,25

Product No.

0221 013

0276 002

0001 004

       

CONSTRUCTION

Inner conductor:

material

CuSn

Cu

Cu

number and diameter of wires [mm]

19x0,18

1x1,0

1x1,63

diameter [mm]

0,9

1,0

1,63

Insulation:

material

PE

foam-skin PE

foam-skin PE

diameter [mm]

2,95

4,8

7,25

Outer conductor:

material and CONSTRUCTION

braid CuSn
Al/Cop tape

Al/PETP/Al tape
braid CuSn
Al/Cop tape

Al/PETP/Al tape
braid CuSn
Al/Cop tape

Sheath:

material

gel
PE

gel
PE

gel
PE

colour

black

black

black

Diameter Outer [mm]

6,8

8,4

11,5

       

ELECTRICAL PARAMETERS AT 20°C

Characteristic impedance [Ω]

50 ± 2

75 ± 3

75 ± 3

Capacitance [pF/m] przy f=1 kHz

103,0

60,0

60,0

Velocity of propagation [%]

66

78

78

DC resistance [mΩ/m]:

inner conductor

32,5

22,0

8,0

outer conductor

13,4

9,2

8,5

Attenuation [dB/100 m] – average, at frequency [MHz]:

 

50

11,4

4,6

3,1

100

16,6

6,4

4,4

200

24,4

9,1

6,4

800

73,0

20,2

14,4

1000

87,0

22,0

16,7

2400

 

38,5

31,0

Return loss [dB] - min.

20

20

20

Shielding attenuation [dB] - min.

75

75

75

       

OTHERS DATA

Reference standards

MIL-C-17

IEC 60096-2A
PN-EN 50117

IEC 60096-2A
PN-EN 50117

Operating temperature range [°C]

-40 ¸ +70

-40 ¸ +70

-40 ¸ +70

Minimum bending radius [mm]

70

90

120

Weight [kg/km]

58

74

111,0

 

SPECIAL CABLES PS-Y-29
Technical Data sheet

acrobat reader_50x50
 
APPLICATIONS

Hybrid cables PS-Y-29 intended for operation in CCTV networks.

Cables are equipped with coax WD 75-0,59/3,7 for visual signal transmission and a group of insulated conductors for camera power supply and control signals transmission.

The cables are suitable for fixed indoor and outdoor installations.

CONSTRUCTION

coaxial cable WD 75-0,59/3,7

- soft solid copper conductor, diameter 0.59 mm,

- polyethylene (PE) insulation, diameter 3.7 mm,

- copper wire braid,

LiY wires

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

- PVC insulation - identification colour code in accordance with DIN VDE 47100,

- insulated conductors twisted into pair,

- pair wrapped in polyester tape,

PS-Y-29 cable

- white (RAL 9010) PVC cable sheath, (8 shape) extruded on the parallel arranged coaxial and pair of insulated conductors, other colours also available.
 
CHARACTERISTICS

Coaxial cable WD 75-0,59/3,7

Characteristic impedance 75 ± 3 Ω

Capacitance at 1 kHz, approximate 67 nF/km

Velocity of propagation 66 %

DC resistance at 20°C, approximate

inner conductor 63 Ω/km

outer conductor 27.2 Ω/km

LiY wires

Operating voltage Uo/U 300/300 V

Operating voltage, peak value 500 V

Voltage test 1500 V rms

DC conductor resistance at 20°C, maximum:

conductor 0.50 mm2 39.0 Ω/km

conductor 0.75 mm2 26.0 Ω/km

conductor 1.0 mm2 19.5 Ω/km

Insulation resistance, minimum 20 MΩ∙km

Inductance, approximate 0.7 mH/km

Cable PS-Y-29

Operating temperature range

during operation from - 30 to + 70°C
during installation from - 10 to + 50°C

Minimum bending radius 10 x cable diameter

Cable combustibility flame retardant

Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2

Reference standards

coaxial cable PN-91/T-90601, IEC 61156-1

LiY wires DIN VDE 0812

The cable meets requirements of the low voltage directive 2014/35/EU

Attenuation loss [dB/100m] average - at frequency [MHz]:

1

1.0

50

7.4

100

10.5

200

15.1

300

18.8

500

24.8

800

32.0

1000

36.3

1500

45.6

2000

55.7

2400

56.9

 

Other cross-sections and conductor counts available on request.

TECHNOKABEL S.A. reserves the right to change specifications without prior notice.

 

RG 108 A/U 78Ω Technical Data sheet

acrobat reader_50x50
APPLICATIONS

Cable RG 108 A/U intended for operation in IBM cash registers.

To achieve high analogue or digital data transmission performance the cable is protected against external electromagnetic interferences by an overall shield.

The cables are suitable for indoor installations connecting fixed and movable equipment.

CONSTRUCTION

- flexible, multiwire conductors, stranded of tin-plated copper wires, cross-section 0.5mm2 (7x0.3 mm),

- polyethylene (PE) insulation - diameter 2.0 mm,

- insulated conductors twisted into pair,

- pair wrapped in polyester tape,

- tinned copper wire braid shield, density of coverage bigger than 85%,

- PVC cable sheath, colours on request.

CHARACTERISTICS

Characteristic impedance 78 ± 7 Ω

Mutual capacitanceat at 1 kHz 68 ± 5 nF/km

DC conductor resistance at 20°C, approximate 34.5 Ω/km

DC screen resistance at 20°C,approximate 18.0 Ω/km

Operating temperature range: from - 30 to + 70 °C

Minimum bending radius:

single 30 mm

multiple 90 mm

Cable combustibility flame retardant

Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2

Reference standards MIL-C-17/45ETIA/EIA 568 A

Attenuation loss, approximate

f

MHz

1

2

3

5

7

10

20

30

50

70

100

a

dB/100 m

2.5

3.7

4.6

6.1

7.2

8.5

12.1

14

17.2

20.2

26.0

The cable meets requirements of the low voltage directive 2014/35/EU