RIBBON CABLES Technical Data sheet
 Declaration

 

 acrobat reader_50x50  acrobat reader_50x50

APPLICATIONS

TLWY are ribbon cables designed for control cabinets, electronic devices and others as interconnection cables for electronic modules, equipment and instruments.

Cables are designed to allow easy separation of any number of wires.

CONSTRUCTION

- flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting requirements of class 5 per PN-EN 60228,

- PVC insulation - colours of insulation and their sequence according to the following table, other combinations of colours are available on request:

No. wires

colour of insulation

1  8  15  22

red

2  9  16  23

blue

3 10 17 24

black

4 11 18 25

white

5 12 19 26

green

6 13 20 27

brown

7 14 21 28

yellow

- insulated conductors arranged parallel to each other and glued together.

CHARACTERISTICS

Conductor cross-section

mm2

0.124

0.14

0.22

0.35

0.5

0.75

1.0

1.5

Operating voltage, peak value

V

150

150

150

150

300

300

300

300

Voltage test

V rms

500

500

1000

1500

1500

1500

2000

2000

Insulation resistance, minimum

MΩ·km

50

200

200

200

200

200

200

200

DC conductor resistance at 20°C, maximum

Ω/km

155

144

89.3

57.2

38.8

25.8

19.1

13.3

 

Operating temperature range

      for fixed installation               from - 30 to + 70°C
      for movable installation          from   - 5 to + 50°C

Minimum bending radius       10 x wire height

Cable combustibility             flame retardant

Combustibility tests             PN-EN 60332-1-2, PN-EN 60332-2-2, IEC 60332-1-2, IEC 60332-2-2

Reference standards           PN-91/T-90211

 

The cable meets requirements of the low voltage directive 2014/35/EU

Other cross-sections and conductor counts available on request.